Product Details:
|
Refrigerant: | R22,R134a,R407C,R410A | Application: | Chiller Industry |
---|---|---|---|
Circuit: | Double Circuit | Cooling Capacity: | 18KW~3000KW |
Heat Exchange Tube: | Copper Tube | Color: | Customized |
High Light: | 18KW Shell And Tube Condenser,Double Circuits Shell And Tube Condenser,270KW shell and tube type condenser |
18kw shell and tube type condenser straight tube double circuits
U Shaped Tube Dry Type Evaporator (Single Circuit)
(Capacity) 18KW TO 270KW
Models
|
QXU18S5 | QXU47S6 | QXU65S8 | QXU135S8 | QXU185S10 | QXU270S10 | ||
Rated data Refrigerant R22 ti=12°C te=2°C tu=7°C Dts=5°C |
Qn | KW | 18.6 | 47 | 65 | 135 | 185 | 270 |
Kcal/h (×103 ) |
16 | 40.4 | 56.7 | 116 | 159 | 232 | ||
Wn | m3 /h | 4 | 8 | 11.4 | 23.2 | 31.8 | 46.4 | |
Wm | m3 /h | 6.3 | 11.4 | 14.5 | 28 | 41 | 65 | |
Dpn | bar | 0.16 | 0.41 | 0.39 | 0.44 | 0.36 | 0.42 | |
Size(mm) |
A | 887 | 1407 | 1431 | 2115 | 2320 | 2654 | |
B | 140 | 168 | 219 | 219 | 273 | 273 | ||
C | 97 | 107 | 161 | 180 | 200 | 234 | ||
D | 690 | 1190 | 1180 | 1830 | 2000 | 2280 | ||
E | 180 | 200 | 200 | 240 | 300 | 300 | ||
Inlet/Outlet Size |
W(DN) | 40 | 50 | 65 | 80 | 100 | 100 | |
D1(mm) | 22 | 22 | 22 | 35 | 35 | 35 | ||
D2(mm) | 35 | 35 | 54 | 54 | 67 | 80 | ||
Weight | kg | 49 | 78 | 93 | 155 | 232 | 289 | |
Notes: Qn Rated Refrigerating Capacity Wn Cooling Water Flow Wm Maximum Cooling Water Flow Dpn Circulating Cooling Water Pressure Drop Dts Superheat Temperature |
U Shaped Tube Dry Type Evaporator (Double Circuit)
(Capacity) 35KW TO 310KW
Models
|
QXU35D6 | QXU65D8 | QXU95D8 | QXU185D10 | QXU270D10 | QXU310D10 | ||
Rated data Refrigerant R22 ti=12°C te=2°C tu=7°C Dts=5°C |
Qn | KW | 35 | 65 | 95 | 185 | 270 | 310 |
Kcal/h (×103 ) |
30.2 | 56.7 | 81.7 | 159 | 232 | 267 | ||
Wn | m3 /h | 6 | 11.4 | 16.4 | 31.8 | 46.4 | 53.3 | |
Wm | m3 /h | 10 | 14.5 | 21 | 41 | 65 | 68 | |
Dpn | bar | 0.27 | 0.39 | 0.46 | 0.36 | 0.42 | 0.43 | |
Size(mm) |
A | 1275 | 1431 | 1781 | 2320 | 2654 | 2654 | |
B | 168 | 168 | 219 | 219 | 273 | 273 | ||
C | 107 | 161 | 200 | 200 | 234 | 234 | ||
D | 1040 | 1180 | 1530 | 2000 | 2280 | 2280 | ||
E | 200 | 240 | 240 | 300 | 300 | 300 | ||
Inlet/Outlet Size |
W(DN) | 50 | 50 | 65 | 89 | 114 | 114 | |
D1(mm) | 16 | 22 | 22 | 22 | 35 | 35 | ||
D2(mm) | 22 | 35 | 35 | 42 | 54 | 54 | ||
Weight | kg | 72 | 93 | 136 | 232 | 279 | 296 | |
Notes: Qn Rated Refrigerating Capacity Wn Cooling Water Flow Wm Maximum Cooling Water Flow Dpn Circulating Cooling Water Pressure Drop Dts Superheat Temperature |
The hot medium of the water-cooled cooler is the inlet of the pipe, which flows in a tortuous way to the outlet of the pipe through each channel.The cooler medium adopts double pipe flow, that is, the cooler medium enters half of the cooler tube from the water inlet through the dividing water cover, and then flows into the other half of the cooler tube from the return water cover to the other side of the dividing water cover and the outlet pipe.In the process of double-pipe flow, the waste heat from absorbing medium is discharged from the outlet, so that the working medium keeps the rated working temperature.
COOPERATED CLENTS
Contact Person: Mrs. Nichole Deng
Tel: 15527011936
Fax: 86-27-8337-2527