Send Message
Home ProductsHigh Pressure Heat Exchanger

Cotton Insulation Tubular Heat Exchanger Double Circuit Air Conditioning System

Certification
China Wuhan Qiaoxin Refrigeration Equipment CO., LTD certification
China Wuhan Qiaoxin Refrigeration Equipment CO., LTD certification
I'm Online Chat Now

Cotton Insulation Tubular Heat Exchanger Double Circuit Air Conditioning System

Cotton Insulation Tubular Heat Exchanger Double Circuit Air Conditioning System
Cotton Insulation Tubular Heat Exchanger Double Circuit Air Conditioning System

Large Image :  Cotton Insulation Tubular Heat Exchanger Double Circuit Air Conditioning System

Product Details:
Place of Origin: CHINA
Brand Name: GREEFOUN
Certification: CE
Model Number: QXU148S8
Payment & Shipping Terms:
Minimum Order Quantity: 1piece
Packaging Details: Standard Export Package
Delivery Time: within 15days
Payment Terms: TT, L/C, Western Union
Supply Ability: 100000pieces/year

Cotton Insulation Tubular Heat Exchanger Double Circuit Air Conditioning System

Description
Refrigerant: R134a Connection Type: Tenon Surface
Refrigerating Medium: Tap/underground/river/sea Water, Brine, Glycol/sulfate Solution Cooling Capacity: 18KW~4000KW
Heat Exchange Tube: Copper Nickel Alloy Application: Refrigeration Industry
High Light:

high pressure shell and tube heat exchanger

,

shell type heat exchanger

 

Cotton Insulation Tubular Heat Exchanger Double Circuit Air Conditioning System

 
Soil Heat Exchanger Ground Source Air Conditioning System.
 
This air conditioning system is the heat exchanger buried in the ground, through the water in the high-
 
strength plastic pipe composed of closed loop circulation, in order to achieve the purpose of hot and cold
 
with the earth soil exchange.
 
Summer through the unit will be the heat transfer to the ground, the room for cooling. While storing heat
 
for winter use. In winter, the heat in the soil is transferred to the room through the heat pump, and the
 
room is heated and stored for the summer.
 
The earth's soil provides a good free energy storage source, thus realizing the seasonal transformation of
 
energy. Vertical Buried Ground Source Heat Pump System Horizontal Buried Ground Source Heat Pump
 
System
 
<1> Principle of Operation: Ground Source Heat pump air conditioning is a "heat pump" (cooling, heating).
 
Heating, it absorbs geothermal discharge to the user, this process consumes only a small amount of
 
power, as shown in Figure 1. Cooling, it absorbs the user's indoor heat to the underground discharge,
 
also consumes a small amount of heat.
 
<2> unit operation process: the winter heat pump in the positive flow of refrigerant, the compressor
 
discharge of high temperature and high pressure R22 gas into the condensation To the water in the water
 
collector to release heat, the phase change to high temperature and high pressure of the liquid, and then
 
by the thermal expansion valve throttle pressure into low temperature and low pressure liquid into the
 
evaporator, from the underground circulating fluid to absorb low temperature heat phase change Low
 
temperature and low pressure saturated steam into the compressor suction side, compressed by the
 
compressor to discharge high temperature and high pressure gas to complete a cycle. So the cycle of
 
underground low-temperature heat "handling" to the sump, which continue to provide users with 45 ℃ -50
 
℃ hot water.
 
3. Summer heat pump in the reverse flow of refrigerant, and the user heat exchanger into the evaporator
 
from the collector in the low-temperature water (7-12 ℃) to extract heat, and underground heat exchanger
 
evaporator into the condenser to the Underground circulation liquid discharge heat, circulating fluid heat
 
and then to the underground low-temperature area emissions, so the cycle to continue to provide users
 
with 7-12 ℃ cold water.

 

U SHAPED TUBE DRY EVAPORATOR (DOUBLE CIRCUIT)

 

CAPACITY: 120KW TO 310KW
 

Models  QXU120D8QXU135D8QXU155D8QXU185D10QXU220D10QXU270D10QXU310D

Rated data
Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

QnKW120135155185220270310

Kcal/h
(×103 )

103.2116133.3159189232267
Wnm3 /h20.623.226.731.837.846.453.3
Wmm3 /h25283041436568
Dpnbar0.410.440.370.360.430.420.43

 

ModelsQXU120D8QXU135D8QXU155D8QXU185D10QXU220D10QXU270D10QXU310D10

Dimension
(mm)

A1815211523152320232026542654
B219219219219273273273
C200200200200234234234
D1530183020302000200022802280
E240240240300300300300
VentS11/21/21/21/21/21/21/2
OutletS21/21/21/21/21/21/21/2
ConnectionW(DN)89898989114114114
D1(mm)22222222353535
D2(mm)42424242545454
P(kg)145155163232255279296

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature

 
COOPERATED CLENTS
Cotton Insulation Tubular Heat Exchanger Double Circuit Air Conditioning System 0

Contact Details
Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Contact Person: Mrs. Nichole Deng

Tel: 15527011936

Fax: 86-27-8337-2527

Send your inquiry directly to us (0 / 3000)